Review article

Limitation of the oscillation amplitude of the premise temperature in the warm period of the year

UDC: 

697.94+628.8

DOI: 

10.23968/1999-5571-2017-14-2-188-194

Pages: 

188-194

Annotation: 

It is proposed to limit the amplitude of temperature changes for lowering the temperature of premises during the warm period of year in regions with the average monthly temperature in July as 21°C and above. Herewith, influence on temperature of not only the sun protection, mandatory to installation according to operating standards, but also of the properties of filling of the light opening, and internal thermal stability of premises is considered.

Authors: 

Malyavina E. G. National Research Moscow State University of Civil Engineering

Usmonov Sh. Z. Khujand Polytechnic Institute of Tajik Technical University named after Academician M. S. Osimi

Links to authors' articles: 

Journal Issue