Annotation:
The article is devoted to determination of the infiltration water volume entering centralized water disposal systems. The analysis of the currently used calculation methods and the main factors influencing the formation of infiltration water volumes is given. New approaches and calculated dependences are proposed that allow taking into account the degree of wear and material of pipelines when determining the volume of incoming infiltration water from areas, where sections of gravity pipelines are temporarily or permanently located below the ground water horizon.
Keywords: