Review article

Visual analysis of the condition of building structures of civil facilities after severe high water condition and floodson the example of the Orenburg region

UDC: 

624.07

DOI: 

10.23968/1999-5571-2026-23-4-16-25

Pages: 

16-25

Annotation: 

The article presents the results of the assessment of the technical condition of residential buildings` structures after the large-scale flood in 2024 in the Orenburg Region. The study was carried out using visual inspection and engineering analysis of the load-bearing and enclosing structures exposed to prolonged floodwater impact. It was established that the structures of external walls made of expanded clay blocks with a facing layer of hollow facing bricks and mineral wool insulation had been subjected to the greatest damage in the form of water saturation, deformations and cracks. A weakening of material adhesion and deterioration of the insulation layer were also observed. The study results highlight the necessity of revising the structural design solutions to improve the moisture resistance of envelope systems and to ensure the reliable operation of buildings under conditions of potential flooding and changes in hydrological regimes.

Authors: 

Bogomazov A. S. JSC Research Center of Construction Moscow, Russia

Belash T. A. JSC Research Center of Construction Moscow, Russia

Links to authors' articles: 

Journal Issue