Review article

Free vibrations of thin-walled large-diameter gas pipelines at semi-underground laying

UDC: 

624.074.433

Pages: 

114-120

Annotation: 

The paper presents a solution of the problem of free bending vibrations of a thin-walled large-diameter pipeline laid in the ground to a depth equal to the pipe diameter. The pipeline is regarded as a cylindrical shell subjected to the action of stationary internal operating pressure, the parameter of the longitudinal compressive force, and non-uniform distributed load caused by bearing pressure of soil directed to the outer surface of the pipe.

Authors: 

Sokolov V. G. Tyumen Industrial University

Razov I. O. Tyumen Industrial University

Links to authors' articles: 

Journal Issue